PN |
Signal Type |
Fmin [MHz] |
Fmax [MHz] |
Power [dBm] |
Eff [%] |
SS Gain [dB] |
Sat Gain [dB] |
Vdd [V] |
Description |
SG26F30S-D |
Pulsed |
2090 |
2190 |
47 |
NA |
19.97 |
17.39 |
48 |
LTE application with ET |
SG26F30S-D |
Pulsed |
1750 |
1950 |
47 |
NA |
20.34 |
18.8 |
50 |
LTE wireless network |
SG26F30S-D |
Pulsed |
2500 |
2700 |
46.5 |
NA |
18.37 |
16.75 |
48 |
LTE wireless network |
SGFCF2002S-D |
CW |
600 |
1000 |
40.5 |
47.5 |
30.5 |
25.0 |
28 |
proprietary HD video distribution system utilizing QAM modulation |
SGFCF2002S-D |
CW |
200 |
2600 |
41.0 |
41.8 |
13.8 |
12.2 |
36 |
wideband PMR application, final stage only |
SGFCF2002S-D |
CW |
750 |
780 |
45.0 |
0.6 |
25.0 |
20.8 |
50 |
LTE application, final stage only |
SGFCF2002S-D |
Pulsed |
750 |
780 |
45.0 |
NA |
25.0 |
23.8 |
50 |
LTE application, final stage only |
SGFCF2002S-D |
CW |
20 |
600 |
41.5 |
60.3 |
34.0 |
29.0 |
28 |
wideband PMR application |
SGFCF2002S-D |
CW |
1580 |
1700 |
39.5 |
65.4 |
31.6 |
30.5 |
24 |
asset tracking application |
SGFCF2002S-D |
CW |
1580 |
1700 |
43 |
53.3 |
32.7 |
30.6 |
40 |
asset tracking application |
SGFCF2002S-D |
CW |
90 |
520 |
40 |
64.9 |
41.5 |
38.8 |
16/28 |
wideband PMR application |
SGFCF2002S-D |
Pulsed |
2090 |
2190 |
45 |
NA |
34.67 |
32.04 |
48 |
LTE application for small cell |
SGFCF2002S-D |
CW |
1330 |
1410 |
42.75 |
63.5 |
36.81 |
33.79 |
28 |
wireless mesh data network |
SGFCF2002S-D |
CW |
790 |
830 |
41.5 |
49.77 |
34.07 |
30.97 |
28 |
FM radio link |
SGFCF2002S-D |
CW |
27 |
27 |
37 |
74.23 |
44.35 |
41.13 |
19 |
wireless power transmission |
SGFCF20S-D |
CW |
1580 |
1700 |
41.5 |
71.5 |
19.4 |
16.9 |
28 |
asset tracking application, special permission requested to recommend CW operation at drain voltage of 28V |
SGFCF20S-D |
CW |
1580 |
1700 |
40.5 |
75.7 |
19.0 |
16.6 |
24 |
asset tracking application, special permission requested to recommend CW operation at drain voltage of 28V |
SGFCF20S-D |
Pulsed |
1330 |
1410 |
42.75 |
NA |
18.96 |
16.62 |
28 |
wireless mesh data network |
SGFCF20S-D |
Pulsed |
2200 |
2500 |
42 |
NA |
15.97 |
14.55 |
28 |
wireless mesh data network |
SGFCF20S-D |
Pulsed |
2500 |
2700 |
44.5 |
NA |
18.52 |
16.19 |
48 |
LTE wireless network |
SGN350H-R / SGFCF2002S-D |
Pulsed |
1000 |
1150 |
55.95 |
56.95 |
NA |
48.95 |
50 |
avionics radar application |
SGNH130M1H |
Pulsed |
900 |
1250 |
51.5 |
NA |
17.03 |
16.03 |
50 |
Link 16 application, 10us pulse @ 10% duty |
SGNH130M1H |
CW |
1000 |
2500 |
51 |
48.87 |
11.37 |
9.34 |
50 |
wideband lab amp |
SGNH130M1H |
Pulsed |
1300 |
1900 |
52.25 |
NA |
14.07 |
12.2 |
50 |
Link 16 application, 10us pulse @ 10% duty |
SGFCF2002S-D |
Pulsed |
2700 |
3100 |
43.75 |
48 |
NA |
28.75 |
50 |
Pulsed RADAR, both stages biased class C, 400us @ 20% Duty |
SGFCF30T-D |
Pulsed |
1700 |
2900 |
44.77 |
43 |
15.47 |
14.2 |
50 |
wideband small cell final amplifier |
SGFCF2002S-D |
Pulsed/CW |
958 |
998 |
44.5 |
69 |
NA |
36.68 |
50 |
ADS-B amplifier for General Aviation and UAT |
SGN350H-R |
Pulsed |
1090 |
1090 |
56.5 |
76.61 |
18.93 |
16.14 |
50 |
ADS-B amplifier for General Aviation |
SGN350H-R |
Pulsed |
1000 |
1120 |
56.5 |
66.7 |
16 |
14 |
50 |
L-Band Radar, Link 16 application |
SG26F30S-D Doherty |
Pulsed |
2500 |
2700 |
50 |
47 |
15 |
15 |
50 |
Symmetric Doherty for LTE, WCDMA, OFDM signals |
SGNH130M1H |
Pulsed |
1090 |
1090 |
53.5 |
65 |
18.85 |
15.48 |
50 |
ADS-B amplifier for General Aviation, biased class C |